ErrorPlease complete all the required fields (*). Recuerde, el prefijo y teléfono es necesario.

External wall awrhhi04a-00

  • Reference

    awrhhi04a-00

  • Manufacturer

    dataholz.eu

  • Phone

    43 - (0) 1 798 26 23-0


  • Publication date

    06-Aug-2020

  • Product type

    Assembly required

  • Serie

    awrhhi04a-00

  • File Language

    EN Language English

  • Standard

    GDO-BIM

  • Format Autodesk AutocadAutodesk RevitIFCPDF


My projects

Prescribe your projects

Contact

Contact the manufacturer

Technical support

BIM Technical Support Request

Downloads

Download BIM object

Budget

Request quotation

Another BIM File

Request the product in other software and version

Recommends

Recommends
Reference: awrhhi04a-00
Unit price: Consult the product data sheet.
Presentation and sale of the product:

External wall timber frame construction, ventilated, with dry lining, with cladding

Element solutions, provided by Dataholz.de

Description:

Building physical assessment

Fire Perfomance REI from inside 60
REI from outside 30

maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by MA39

Thermal Performance U 0,21 W/(m2K)
Diffusion Adequate

Classified by MA39

Acoustic Performance Rw (C;Ctr) 50 dB (-3; -10)
Ln,w (Cl)

Battens for the ventilation space screwed onto the structural timber together with vertical battens for the dry lining screwed directly onto the ledger beams will result in Rw(C;Ctr)=43(-1;-5)
Classified by MA39

Mass per unit Area m 41,8 kg/m2

Calculation based on gypsum plaster board type DF GKF

General conditions: Consult the product data sheet.
Country of sale: Austria,
Masterformat Code - Description: 10 22 00 - Partitions,
UNSPSC Code: -
UNSPSC Description: -
Uniclass 2.0 Code: Ee_25_25
Uniclass 2.0 Description: Internal Walls
OmniClass Code: 23-15 11 11
OmniClass Description: Fixed Partitions
COBie Category: IfcWall
IFC Description: IfcWall:
Certificates: -
Expected service life: Consult the product data sheet.
Height ( m ): 0.00
Width ( m ): 0.00
Depth ( m ): 0.00
Technical characteristics:

Building physical assessment

Fire Perfomance REI from inside 60
REI from outside 30

maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by MA39

Thermal Performance U 0,21 W/(m2K)
Diffusion Adequate

Classified by MA39

Acoustic Performance Rw (C;Ctr) 50 dB (-3; -10)
Ln,w (Cl)

Battens for the ventilation space screwed onto the structural timber together with vertical battens for the dry lining screwed directly onto the ledger beams will result in Rw(C;Ctr)=43(-1;-5)
Classified by MA

Materials and finishes:

Register of building materials used for this application, cross-section

Exterior
Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1600 D
C 15,0 fibreboard (MDF) 0,140 11 600 1700 D
D 160,0 construction timber (60/..; e=625) 0,120 50 450 1600 D
E 160 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
F 15,0 OSB 0,130 200 600 1,700 D
G 40,0 spruce wood cross battens (a=400) resp. battens offset 0,12 50 450 1,600 D
H 40,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
Interior
Energy cost: 26,2 , Calculated by HFA
Low emissivity material: -
Low emissivity finish: -
Percentage of recycled materials: -
Environmental data URL: -
General environmental data: -
Product url:
Installation:
Maintenance:
CE certificate:
Cookie Policy